Customization: | Available |
---|---|
After-sales Service: | Yes |
Warranty: | 1~24 Months |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
1. Adopting high-frequency design, high power density, small size and high overall efficiency;
2.Bidirectional energy storage design can realize bidirectional flow control of electric energy,
and both photovoltaic and mains power can charge the battery;
3. Ultra-wide MPPT range, as low as 80Vdc;
4. The working mode can be set (on-grid mode, off-grid mode, hybrid mode);
5. Equipped with output priority setting function;
6. With charging priority setting function;
7. Equipped with lithium battery BMS communication function;
8. Support battery-less operation mode;
9. Supports the use of smart meters to prevent backflow when running on the grid.
Specification | |||||||||||
Model HF | 50248 | 60248 | 80248 | 10348 | 12348 | ||||||
PV | Max PV Input Power | 6000W | 6000W | 4500W*2 | 6000W*2 | 6000W*2 | |||||
MPPT Tracking Voltage Range | 120VDC-450VDC | ||||||||||
Rated Voltage | 360VDC | ||||||||||
Max PV Input Voltage voc (at the lowest temperature) |
500VDC | ||||||||||
Max PV Input Current | 27A | 18A*2 | 27A*2 | ||||||||
MPPT Tracking Channels (Input Routed ) |
1 Routed | 2 Routed | |||||||||
Battery& Charging |
Battery Type | Lead-acid Battery/Lithium Battery | |||||||||
Custom Battery (Charging and discharging paramcters of different types of batteriescan be set through the operation board) | |||||||||||
Rated Battery Voltage | 48VDC | ||||||||||
Battery voltage Range | 42~60VDC(default) | ||||||||||
Max PV Charging Current | 120A | 150A | 180A | 200A | |||||||
Max AC Charging Current | 80A | 100A | 120A | 140A | |||||||
Max Charging Current | 120A | 150A | 180A | 200A | |||||||
On-Grid Operation | |||||||||||
On-Grid Output (AC) |
Rated Output Power | 5000W | 6000W | 8000W | 10KW | 12KW | |||||
Rated Output Voltage | 220VAC/230VAC/240VAC | ||||||||||
Grid Voltage Range | 187VAC~264VAC | ||||||||||
Rated Output Frequency | 50Hz/60Hz | ||||||||||
Frequency Range | 47Hz~52Hz(50Hz),57Hz~62Hz(60Hz) | ||||||||||
Rated Output Current | 22.7A/21.7A/20.8A | 27.3A/26.1A/25A | 36.4A/34.8A/33.3A | 45.5A/43.5A/41.7A | 54.5A/52.2A/50A | ||||||
Power Factor | >0.98(Rated Power) | ||||||||||
Off-Grid Operation | |||||||||||
AC Input |
Rated Input voltage | 220V /230V/240V | |||||||||
Mains input voltage range | 165VAC-280VAC/ 120VAC~280VAC(Can be set) | ||||||||||
Rated Input Frequency | 50Hz/60Hz | ||||||||||
Input Frequency Range | 45Hz~55Hz(50Hz),55Hz~65Hz(60Hz) | ||||||||||
AC Output |
Rated Output Power | 5000W | 6000W | 8000W | 10KW | 12KW | |||||
Rated Output Voltage | 220V /230V/240V | ||||||||||
Output Voltage Accuracy | ±2% | ||||||||||
Rated Input Frequency | 50Hz/60Hz | ||||||||||
Output Frequency Accuracy | ±1% | ||||||||||
Output Wave | Pure Sine Wave | ||||||||||
Hybrid Operation (Complementary Mode) | |||||||||||
AC Input |
Rated Input voltage | 220V /230V/240V | |||||||||
Mains input voltage range | 187VAC~264VAC | ||||||||||
Rated Input Frequency | 50Hz/60Hz | ||||||||||
Input Frequency Range | 47Hz~52Hz(50Hz),57Hz-62Hz(60Hz) | ||||||||||
AC Output |
Rated Output Power | 5000W | 6000W | 8000W | 10KW | 12KW | |||||
Rated Voltage Rated | 220VAC/230VAC/240VAC | ||||||||||
Output Current | 22.7A/21.7A/20.8A | 27.3A/26.1A/25A | 36.4A/34.8A/33.3A | 45.5A/43.5A/41.7A | 54.5A/52.2A/50A | ||||||
Regular Parameters | |||||||||||
Maximum Conversion Efficiency (Battery Discharge) |
94%(peak value) | ||||||||||
MPPT Tracking Efficiency | ≥99.9 | ||||||||||
Transfer Time | 10ms(Typical value) | ||||||||||
Display | LCD+LED | ||||||||||
Cooling Method | Cooling fan in intelligent control | ||||||||||
Communication | RS485/Dry Contact/Mobile APP(WIFI Monitoring or GPRS monitoring)(Optional) | ||||||||||
Protection Degree | IP20 | ||||||||||
Installation | Wall-Mounted | ||||||||||
Protection | Battery low voltage alarm | 44VDC(default value) | |||||||||
Battery low voltage protection | 42VDC(default value) | ||||||||||
Anti-islanding protection | ≤2S | ||||||||||
overload power protection | Automatic Protection (battery mode),Circuit Breaker or Insurance (AC mode) | ||||||||||
Inverter output short circuit protection |
Automatic Protection (battery mode),Circuit Breaker or Insurance (AC mode) | ||||||||||
Temperature protection | >90 ºC(Shut down output) |